| Availability | In Stock |
|---|---|
| Condition | Brand New |
the DIN Rail high Power DMX512 constant voltage decoder is specially developed for constant voltage LED lamps. It adopts advanced microcomputer control technology to convert universal DMX512/1990 digital signal to PWM signal. 32 output channels, can be used to control constant voltage single color, color temperature, RGB, RGBW type lamps. DIN Rail/screw dual-use installation method for easy installation.
Feature function:
1. Automatically adapts input voltage DC12V-24V.
2. Input standard DMX512 signal; 3-digital-display shows DMX address code.
3. 6 color changing modes and 10-speed scales.
4. DMX decoding supports 8-bit,16-bit.
5. An indicator of the DMX512 signal receiving status.
6. Wrong wiring protection at DMX port.Power loss memory function.
7. The DIN rail style facilitates the installation of large-scale projects.
Model: BC-632-DIN
Input Voltage: DC12V-24V
Max load current: 32CH×3A
Max Output Power: 1152W (12V) / 2304W(24V)
Input Signal: DMX512/8 bit/16 bit selectable
Output Signal: Constant Voltage PWM
Decode Channel: 32CH
DMX512 socket: RJ45. Terminal Block
Dimension: L218×W90×H58.5(mm)
Weight (G.W): 331g
Standards and Certifications
![]()
3. Control mode settings
(1) The 40-channel decoder can work in five control modes of DIMCTRGBRGBWRGBWY.
(2) The 32-channel decoder can work in four control modes of DIMCTRGBRGBW.
(3) The 24-channel decoder can work in three control modes of DIMCTRGB.
Long press the button No.2 for 2 seconds to enter the control mode setting, the digital tube flashes, press the button No.3 to switch settings, the digital display 1CH, 2CH, 3CH, 4CH, 5CH, corresponding to DIM CT RGB RGBW RGBWY five modes.
When the working mode is RGB, the white light in the built-in mode corresponds to RGB, in the other modes W is ON.
Press and hold button No.2 for 2 seconds to exit the control mode setting. NO operate for 10 seconds, will exit automatically.

Safety warnings
1. To ensure your safety and product proper usage, please read the user manual carefully.
2. To avoid installed the product in a minefield, strong magnetic field, and high voltage area.
3. To ensure the wiring is correct and firm avoiding short circuit damages to components and cause a fire.
4. Please install the product in a well-ventilated area to ensure an appropriate temperature environment.
5. The product must be worked with a DC constant voltage power supply. Please check the consistency of input power with the product, if the output voltage of the power complies with that of the product.
6. Connect the wire with the power on is forbidden. Ensure proper wiring first then check to ensure no shortcircuit, then power on!
7.Dododon't repair it by yourself whenever an error occurs. Contact the supplier for any inquiry.